    FHF06 heat flux sensor

    High temperature foil heat flux sensor for use up to 250 °C; patented technology, flexible, with temperature sensor and thermal spreaders

    Do you need a thin, flexible and sensitive heat flux sensor that can withstand high temperatures? Hukseflux, the world market leader in heat flux measurement, introduces the FHF06 foil heat flux sensor. Rated temperature range is from –70 to +250 °C. FHF06 measures heat flux from conduction, radiation and convection. In case you do not need the high temperature range, look at our FHF05 series. If FHF05 or FHF06 do not comply with your requirements, have a look at other heat flux sensor models for special applications.

    Specifications :

    Measurand– heat flux, temperature

    Measurement range– (-20 to +20) x 10³ W/m²

    View all specifications>

    Would you like a personalised quote?




    or contact us:



    • info@huksefluxindia.com

    • Description
    Description

    Specifications

    FHF06

    Measurand heat flux, temperature
    Outer dimensions foil with guard (25 x 50) x 10⁻³ m
    Measurement range (-20 to +20) x 10³ W/m²
    Temperature sensor type T thermocouple, IEC 60584-1:2013 class 2*
    Thermal spreaders included
    Rated bending radius ≥ 7.5 x 10⁻³ m
    Rated load on cable ≤ 1.6 kg
    Sensor thermal resistance 12 x 10⁻⁴ K/(W/m²)
    Sensor thickness 0.38 x 10⁻³ m
    Uncertainty of calibration ± 5 % (k = 2)
    Sensitivity (nominal) 5 x 10⁻⁶ V/(W/m²)
    Asymmetry < 2 %
    Rated operating temperature range
    Continuous use** -70 to +250 °C
    Cable -70 to +250 °C
    Connection block -70 to +250 °C
    Label at the end of the cable -40 to +120 °C
    IP protection class IP67***
    Rated operating pressure range up to 25 bar
    Standard cable length 2 m
    Options 5 or 10 m cable length; separate cable; without cable****
    * temperature measurement uncertainty: ± 2.5 or 0.0075 × T °C. For details, refer to user manual.
    ** when measuring at temperatures of -160 °C, contact Hukseflux.
    *** sensor is not suitable for continuous exposure to water.
    **** sensor foil only (without cable and connection block) may be used in vacuum.

    Options

    • with 5 or 10 metres cable length
    • separate cable in 2, 5 or 10 metres length
    • sensor foil only, without wiring, without connection block
    • LI19 hand-held read-out unit / datalogger
    NOTE: LI19 measures heat flux only

     

    Downloads

    FHF06 heat flux sensor brochure

    (PDF, 334.77 KB)

    FHF06 heat flux sensor user manual

    (PDF, 1.25 MB)

    Heat flux measurement in high temperature environments

    FHF06 is a high temperature foil heat flux sensor that can be used for temperatures up to 250 °C. This is made possible by its all-polyimide design, not using any glues. Other members of the FHF family, the FHF05 series range, can be used up to 120 °C maximum, which makes the FHF06 unique. The sensor is thin, flexible and versatile. FHF06 measures heat flux through the object in which it is incorporated or on which it is mounted, in W/m².

    The sensor in FHF06 is a thermopile. This thermopile measures the temperature difference across FHF06’s flexible body. A type T thermocouple is integrated as well, to provide a measurement of temperature. The thermopile and thermocouple are passive sensors; they do not require power.

    Multiple small thermal spreaders, which form a conductive layer covering the sensor, help reduce the thermal conductivity dependence of the measurement. With these incorporated spreaders, the sensitivity of FHF06 is independent of its environment.

    Unique features and benefits

    • high temperature resistance up to 250 °C continuous use
    • flexible (bending radius ≥ 7.5 x 10-³ m)
    • low thermal resistance
    • fast response time
    • integrated type T thermocouple
    • robustness, including connection block for strain relief
    • IP protection class: IP67 (essential for outdoor application)
    • integrated thermal spreaders for low thermal conductivity dependence
    • sensor foil only: may be used in vacuum

    Easy to use

    Using FHF06 is easy. It can be connected directly to commonly used data logging systems. The heat flux in W/m² is calculated by dividing the FHF06 output, a small voltage, by the sensitivity. The sensitivity is provided with FHF06 on its certificate and at the end of FHF06’s cable.

    Robust and stable

    Equipped with a connection block, which may serve as strain relief, and with potted protective covers on both sides so that moisture does not penetrate, FHF06 has proven to be very robust and stable.

    FHF06 calibration is traceable to international standards. The factory calibration method follows the recommended practice of ASTM C1130 – 21.

    Working with heat flux sensors

    When used under high temperature conditions, the FHF06 sensitivity to heat flux may be different than stated on its certificate. See the user manual for correcting this temperature dependence. For mounting, see our application note how to install a heat flux sensor.

    Suitable electronics

    The combined measurement of heat flux and temperature offers you a full picture of the thermal behaviour of a system. Heat flux sensor output is a small millivolt signal. Heat flux sensors are often combined with thermocouples. We have several preferred solutions for amplification, data logging and data visualisation. See our application notes on sensor amplification or FHF sensors with Hioki dataloggers.

    Suggested use

    Typical applications for FHF06:
    • monitoring of plastics and composite moulding
    • battery research; thermal runoff
    • analysis of industrial ovens

    Areas of Application

    • Building physics / insulation, thermal comfort and energy budget measurement >
    • Heat flux measurement to validate CFD thermal simulations >
    • Industrial monitoring and control / heat flux and heat transfer measurement >
    • Meteorology / surface energy flux measurement >
    • Scientific research / heat and heat transfer measurement >

    FHF06 heat flux sensor

    • high temperature resistance up to 250 °C continuous use
    • flexible (bending radius ≥ 7.5 x 10-³ m)
    • low thermal resistance
    • fast response time
    • integrated type T thermocouple
    • robustness, including connection block, for strain relief
    • IP protection class: IP67 (essential for outdoor application)
    • integrated thermal spreaders for low thermal conductivity dependence
    • sensor foil only: may be used in vacuum

    Would you like a personalised quote?

    or contact us:

    • info@huksefluxindia.com

    Related products

    Add to quotation basket

    LI19 datalogger

    Heat flux sensors, Heat flux sensors
    Add to quotation basket

    GG01 Gardon gauge

    Heat flux sensors, Heat flux sensors
    Add to quotation basket

    HTR02 series heater

    Heat flux sensors, Heat flux sensors
    Add to quotation basket

    HF03-LI19 heat flux sensor

    Heat flux sensors, Heat flux sensors
    Add to quotation basket

    IHF02 heat flux sensor

    Heat flux sensors, Heat flux sensors
    Add to quotation basket

    HFP01SC heat flux sensor

    Heat flux sensors, Heat flux sensors
    Add to quotation basket

    TRSYS20 thermal resistance measuring system

    Heat flux sensors, Heat flux measuring systems
    Add to quotation basket

    IHF01 heat flux sensor

    Heat flux sensors, Heat flux sensors
    • info@huksefluxindia.com
    • sales@huksefluxindia.com
    Linkedin X-twitter Whatsapp Youtube

    © 2024 HuksefluxIndia

    Cookie & privacy policy

    © Website Designed & Developed By lotus design labs

    • Products
      • Solar radiation sensors
        • Pyranometers
        • Albedometers
        • Pyrheliometers
        • Pyrgeometers
        • Net radiometers
      • Heat flux sensors
        • Heat flux sensors
        • Heat flux measuring systems
        • Soil temperature sensors
    • Applications
      • PV system monitoring
      • Meteorology
      • Building physics
      • Industrial heat transfer
      • Scientific research
      • Thermal simulations
    • Services & Support
      • Application support
      • Pyranometer calibration
      • Downloads
    • News
    • About
    • Contact us
    Quotation Cart
    close
    Start typing to see products you are looking for.