Hukseflux India
  • Products
    • Solar radiation sensors
      • Pyranometers
      • Albedometers
      • Pyrheliometers
      • Pyrgeometers
      • Net radiometers
    • Heat flux sensors
      • Heat flux sensors
      • Heat flux measuring systems
      • Soil temperature sensors
  • Applications
    • PV system monitoring
    • Meteorology
    • Building physics
    • Industrial heat transfer
    • Scientific research
    • Thermal simulations
  • Services & Support
    • Application support
    • Pyranometer calibration
    • Downloads
  • News
  • About
  • Contact us
1 item / ₹1,000.00
1 item / ₹1,000.00
Menu
View cart “SR15-D2A2 pyranometer” has been added to your cart.
  • Home Solar radiation sensors Pyrgeometers IR02-TR pyrgeometer
    IR02 pyrgeometer
    Back to products
    NR01 net radiometer

    IR02-TR pyrgeometer

    Pyrgeometer with heater and 4-20 mA transmitter

    IR02-TR is a pyrgeometer suitable for longwave irradiance measurement in meteorological applications. The instrument can be heated, which improves measurement accuracy as it prevents dew deposition on its window. IR02-TR houses a 4-20 mA transmitter for easy read-out by dataloggers commonly used in the industry.

    Specifications :

    Measurand– longwave radiation

    Optional measurand– sky temperature, surface temperature

    View all specifications>

    Would you like a personalised quote?




    or contact us:



    • info@huksefluxindia.com

    • Description
    Description

    Specifications

    IR02-TR

    Measurand longwave radiation
    Optional measurand sky temperature, surface temperature
    Spectral range 4.5 to 42 x 10⁻⁶ m
    Field of view angle 150 °
    Response time (95%) 18 s
    Rated operating temperature range -40 to +80 °C
    Transmitted range -300 to 100 W/m²
    Temperature dependence < ± 3 % (-10 to +40 °C)
    Calibration traceability to WISG
    Optional traceability to blackbody (ITS-90)
    Heater 12 VDC, 1.5 W
    Temperature sensor Pt100
    Standard cable length 5 m (see options)

    Options

    • longer cable, in multiples of 5 metres
    • blackbody calibration (ITS-90)
    • adapted transmitted range
    • IR02 version without transmitter

    Downloads

    IR02-TR pyrgeometer brochure

    (PDF, 232.27 KB)

    IR02-TR pyrgeometer with heater

    IR02-TR measures the longwave or far-infra-red radiation received by a plane surface, in W/m², from a field of view angle of approximately 150°. Longwave radiation is the part of radiation that is not emitted by the sun. The actual field of view angle of IR02-TR is not the ideal 180°. The reduction of this field of view makes it possible to offer an instrument at an attractive price level, while the accuracy loss is relatively small. IR02-TR has a window with a cut-on at 4.5 x 10⁻⁶ m, making it suitable for day- and night observations.

    Operation

    Using IR02-TR is easy. The pyrgeometer can be connected directly to commonly used data logging systems. The irradiance in W/m² is calculated by using the transmitter’s output and the temperature reading. The final result is calculated taking into account the irradiance radiated by the sensor itself (Stefan-Boltzmann law). In IR02-TR’s standard configuration, the 4 to 20 mA output corresponds to a transmitted range of -300 to +100 W/m² . This range can be adjusted at the factory upon request.

    IR02-TR Design

    IR02-TR pyrgeometer employs a thermal sensor with black coating, a flat silicon window with solar blind filter and an anodised aluminium body. IR02-TR houses an on-board heater. Heating prevents condensation of water on the pyrgeometer window which, when occurring, leads to very large measurement errors. IR02-TR has a high sensitivity. With the transmitter a typical datalogger no longer contributes to the uncertainty of the measurement.

    Suggested use

    • general meteorological observations
    • climatological networks
    • agricultural warning networks (frost)

    Areas of Application

    • Meteorology / surface energy flux measurement >

    IR02-TR pyrgeometer

    • suitable for day- and night observations
    • on-board heater. Heating prevents condensation of water on the pyrgeometer window which, when occurring, leads to very large measurement errors.
    • high sensitivity

    Would you like a personalised quote?

    or contact us:

    • info@huksefluxindia.com

    Related products

    Add to quotation basket

    SRA30-M2-D1 albedometer

    Solar radiation sensors, Albedometers
    Add to quotation basket

    DP01

    Solar radiation sensors, Pyranometers
    Add to quotation basket

    VMA01 adapter plate

    Solar radiation sensors, Pyranometers
    Add to quotation basket

    SRA20-D2 albedometer

    Solar radiation sensors, Albedometers
    Add to quotation basket

    SR30-M2-D1 pyranometer

    Solar radiation sensors, Pyranometers
    Add to quotation basket

    SR05-D2A2 pyranometer

    Solar radiation sensors, Pyranometers
    Add to quotation basket

    SR05-D1A3 pyranometer

    Solar radiation sensors, Pyranometers
    Add to quotation basket

    SR25 pyranometer

    Solar radiation sensors, Pyranometers
    • info@huksefluxindia.com
    • sales@huksefluxindia.com
    Linkedin X-twitter Whatsapp Youtube

    © 2024 HuksefluxIndia

    Cookie & privacy policy

    © Website Designed & Developed By lotus design labs

    • Products
      • Solar radiation sensors
        • Pyranometers
        • Albedometers
        • Pyrheliometers
        • Pyrgeometers
        • Net radiometers
      • Heat flux sensors
        • Heat flux sensors
        • Heat flux measuring systems
        • Soil temperature sensors
    • Applications
      • PV system monitoring
      • Meteorology
      • Building physics
      • Industrial heat transfer
      • Scientific research
      • Thermal simulations
    • Services & Support
      • Application support
      • Pyranometer calibration
      • Downloads
    • News
    • About
    • Contact us
    Quotation Cart
    close
    Start typing to see products you are looking for.