Hukseflux India
  • Products
    • Solar radiation sensors
      • Pyranometers
      • Albedometers
      • Pyrheliometers
      • Pyrgeometers
      • Net radiometers
    • Heat flux sensors
      • Heat flux sensors
      • Heat flux measuring systems
      • Soil temperature sensors
  • Applications
    • PV system monitoring
    • Meteorology
    • Building physics
    • Industrial heat transfer
    • Scientific research
    • Thermal simulations
  • Services & Support
    • Application support
    • Pyranometer calibration
    • Downloads
  • News
  • About
  • Contact us
0 items / ₹0.00
0 items / ₹0.00
Menu
  • Home Specials for thermal measurement Thermal properties sensors TP08 thermal properties sensor
    TP02 thermal properties sensor
    Back to products
    GT series

    TP08 thermal properties sensor

    Small size non-steady-state probe for thermal conductivity measurement

    TP08 is a probe that offers the possibility to perform a practical and fast measurement of the thermal conductivity (or thermal resistivity) of the medium in which it is inserted at a high accuracy level. It works in compliance with the ASTM D5334-14, D5930-97 and IEEE 442-1981 standards. The TP08 is a small version of type TP02, made for situations where the length of the TP02 poses a problem. The standard TP08 probe has proven its suitability for soils, thermal backfill materials, sediments, foodstuff, powders, sludges, paints, glues and various other materials.

    Read more >

    Would you like a personalised quote?




    or contact us:



    • info@huksefluxindia.com

    • Description
    Description

    Specifications

    TP08

    Test method ASTM D5334-14 and D5930-97 and IEEE Std 442-1981
    Needle length 70 mm
    Traceability NPL
    Range (λ) 0.1 to 6 W/m.K
    Sensitivity (ΔT) Thermocouple K, ANSI MC96.1-1982
    Temperature range total sensor -55 to +180 °C including cable
    Accuracy (@ 20 °C) ± (3% + 0.02) W/mK
    Temperature dependence of the accuracy ± 0.02 %/K (additional)
    Measurement cycle duration 200 s (typical)
    Power requirements (switched) 3V, 1 Watt (max)
    Medium / sample requirements granular materials, powders, slurries, gels, pastes. Some samples require pre-drilling. Sample size: Min 20 mm radius. Min volume 80 ml. Smaller samples: consult Hukseflux. Caution: please consult the product manual for more details.
    Protection needle and base IP68
    Protection total sensor IP67

    Options

    • Container TP08: Because of the relative importance of the thermal equilibrium between base and sample, an optional container can be ordered with TP08.
    • Alternative designs: Hukseflux is specialised in NSSP design. Alternative models, for instance smaller, more robust or temperature resistant have been manufactured on request.
    • Permanent installation in soils: The dedicated model TP01 is specifically designed for long term monitoring. A separate brochure is available.

    Downloads

    TP08 thermal properties sensor brochure

    (PDF, 144.75 KB)

    TP08 thermal properties sensor user manual

    (PDF, 659.01 KB)

    The Non-Steady-State Probe (NSSP) measurement method (also known as transient line source, thermal needle, hot needle, heat pulse- and hot wire technique) has the fundamental advantages that it is fast and absolute while the sample size is not critical. Hukseflux is specialised in NSSP design. Special models have been developed for in-situ field experiments. For permanent installation in soils, a dedicated model, TP01, is available. TP08 has been designed and tested in collaboration with the Applied Physics Group of Wageningen University.

    Hukseflux specialises in Non-Steady-State probe design. The primary model of the Hukseflux product range is the TP02. This model offers optimal measurement accuracy by a combination of its design features. For some applications however the requirements regarding the sample size are such that the needle length and diameter of the TP02 are too large. For this category of samples, TP08 has been designed. Having a needle length of 70 mm, with the junction at around 17 mm from the tip, and a diameter of 1.2 mm, samples of around 80 ml can be analysed. (35 mm depth). In some cases samples can even be smaller (consult Hukseflux). In TP08 the reference junction of the thermocouple is located in the base. A high quality measurement with TP08 requires that not only the sample but also the base are at a stable (preferably the same) temperature. Usually this is achieved by clamping the base into the same material (metal) that holds the sample.

    Suggested use

    • studies of ocean sediments
    • studies of small samples
    • studies of high cost samples (uranium sludge)

    Areas of Application

    • Geotechnics / soil thermal route analysis >

    GT series

    Guiding tubes for thermal needles TP02, TP07 and TP08

    View product>

    CRC series

    Calibration reference cylinders for thermal needle probes TP02/TP08, TP07 and TP09

    View product>

    TP08 thermal properties sensor

    • the standard TP08 probe has proven its suitability for soils, thermal backfill materials, sediments, foodstuff, powders, sludges, paints, glues and various other materials.
    • practical and fast measurement of the thermal conductivity (or thermal resistivity) of the medium in which it is inserted at a high accuracy level

    Would you like a personalised quote?

    or contact us:

    • info@huksefluxindia.com

    Related products

    Add to quotation basket

    GT series

    Specials for thermal measurement, Thermal properties sensors
    Add to quotation basket

    TNS02 thermal needle set

    Specials for thermal measurement, Thermal conductivity measuring systems
    Add to quotation basket

    MTN02 thermal needle system

    Specials for thermal measurement, Thermal conductivity measuring systems
    Add to quotation basket

    FTN02 thermal needle system

    Specials for thermal measurement, Thermal conductivity measuring systems
    Add to quotation basket

    TP01 thermal properties sensor

    Specials for thermal measurement, Thermal properties sensors
    Add to quotation basket

    TP02 thermal properties sensor

    Specials for thermal measurement, Thermal properties sensors
    Add to quotation basket

    TPSYS20 system

    Specials for thermal measurement, Thermal conductivity measuring systems
    Add to quotation basket

    CRC series

    Specials for thermal measurement, Thermal properties sensors
    • info@huksefluxindia.com
    • sales@huksefluxindia.com
    Linkedin X-twitter Whatsapp Youtube

    © 2024 HuksefluxIndia

    Cookie & privacy policy

    © Website Designed & Developed By lotus design labs

    • Products
      • Solar radiation sensors
        • Pyranometers
        • Albedometers
        • Pyrheliometers
        • Pyrgeometers
        • Net radiometers
      • Heat flux sensors
        • Heat flux sensors
        • Heat flux measuring systems
        • Soil temperature sensors
    • Applications
      • PV system monitoring
      • Meteorology
      • Building physics
      • Industrial heat transfer
      • Scientific research
      • Thermal simulations
    • Services & Support
      • Application support
      • Pyranometer calibration
      • Downloads
    • News
    • About
    • Contact us
    Quotation Cart
    close
    Start typing to see products you are looking for.