  • Home Heat flux sensors Heat flux measuring systems TCOMSYS01 Hot Cube
    TRSYS20 thermal resistance measuring system
    Back to products
    STP01 soil temperature sensor

    TCOMSYS01 Hot Cube

    Thermal comfort measuring system – a new tool for research and education

    TCOMSYS01 is a measuring system to help understand and quantify “causes and effect” leading to human thermal comfort. The TCOM01 body is temperature stabilised at 33 °C, so that it offers a relatively direct measurement of the human experience. In essence, TCOM01 is a miniature thermal mannequin, measuring according to the innovative Hot Cube method. The heater power required to keep the TCOM01 at a constant temperature is the main measurand. Incorporating 5 heat flux sensors with a black absorber, it also offers a detailed picture of the heat gain and loss from different directions, and a good indication of convective and radiative asymmetry. Other measurements are sensor body temperature, air temperature and relative humidity. In its standard configuration, the system consists of an MCU (Measurement and Control Unit) and a TCOM01 sensor. The MCU offers direct connection to any local area network and “Ethernet over USB”. TCOM01 is also available as a sensor only.

    Specifications :

    Measurand– heating power for stabilisation, heat flux (5x), ambient air temperature, relative humidity, TCOM01 body temperature

    View all specifications>

    Would you like a personalised quote?




    or contact us:



    • info@huksefluxindia.com

    • Description
    Description

    Specifications

    TCOMSYS01

    Measurand heating power for stabilisation, heat flux (5x), ambient air temperature, relative humidity, TCOM01 body temperature
    TCOMSYS01 specifications
    TCOM01 temperature setting 33 °C (user adjustable)
    Included cable 2 x cable with 2 connectors (1.5 m)
    Standard rated operating temperature range +10 to +25 °C
    Limiting temperature range - 25 to +50 °C
    Required data analysis to be performed by the user
    Data display in web browser
    Start up interval < 10 min
    TCOM01 specifications
    Weight 1.12 kg
    Temperature sensor 10 kΩ thermistor
    IP protection class IP65
    Mounting tripod with ¼ inch -20 UNC screw; a Manfrotto Pixi EVO 2-section tripod is included
    MCU specifications
    User interface on MCU as a web page
    Connection via LAN or "Ethernet over USB"
    Voltage measurement accuracy 4 x 10-6 V (0.8 W/m²)
    Rated power supply voltage 10 to 16 VDC
    Adapter power supply 100 – 240 VAC, 50/60 Hz
    Rated operating temperature range MCU - 25 to +50 °C
    Data storage capacity 2GB; > 1 year of data

    Options

    • TCOM01 sensor only
    • extended rated operating conditions; temperature, irradiance, wind speed

    Downloads

    TCOMSYS01 Hot Cube thermal comfort measuring system brochure

    (PDF, 679.32 KB)

    TCOMSYS01 Hot Cube thermal comfort measuring system user manual

    (PDF, 2.08 MB)

    Introduction

    TCOMSYS01 was originally designed to study the effect of radiation sources on human comfort. Equipped with heat flux sensors that measure in 5 directions and a humidity and temperature probe, it offers a good picture of energy gains and losses from all sides to a metal body that thermally resembles the human body; the TCOM01 sensor is in essence a miniature thermal mannequin.

    The TCOMSYS01 system employs dedicated sensors and electronics, measuring thermal comfort according to the new Hot Cube method. The high accuracy of the MCU (Measurement and Control Unit) ensures that TCOMSYS01 will still measure down to very low heat fluxes. The MCU has a robust aluminium housing. The system generates a measurement file, including a time-stamp. The measurement data are stored in the MCU and are later downloaded to a PC. The user is responsible for data analysis.

    How to employ TCOMSYS01

    The primary source of information from TCOMSYS01 simply is the power [W] required to keep the TC0M01 sensor at a constant temperature; a very direct measure of human comfort. This power may be compared to the power required at 20 °C ambient air temperature, no convection (zero wind speed) and no radiation. Power consumption will immediately show if there is a situation of overheating or heatstress or a situation of overcooling or coldstress.

    The second direct information supplied by the heat flux sensors of TCOMSYS01 is the heat loss or gain [W/m²] as a function of direction. If radiative sources are dominant, TCOMSYS01 will measure radiative asymmetry.

    To study the exact effect of radiative sources, in many cases a simple experiment, like switching a radiation source [on] and [off] or shielding a radiation source, can be used to distinguish between convective and radiative heat transport.

    Far-infra red radiation sources may be studied by temporary shielding with silicon wafer. Silicon has around 50 % transmission. Radiation from the sun or lamps may be quantified by shading and unshading.

    To study the insulating effect of clothing, TCOM01 may be insulated using the same fabrics.

    A web browser may be used for real time measurement review, data collection and for changing control settings such as TCOM01 body temperature.

    History

    Already in 1929 the Eupatheoscope (from Greek “wellbeing–emotion–examination”) was designed by A.F. Dufton to quantify the condition in a room from the point of view of comfort. It consists of a blackened cylinder which is controlled to maintain a temperature of 23 °C. The power used is interpreted in terms of equivalent temperatures.

    In the 1990 the company Bruel & Kjear carried a thermal comfort meter (model 1212), based on the same principle, and in addition processing Fangers equation.

    Both models involved only an integrated power measurement. The new Hot Cube method improves on this by incorporating omnidirectional heat flux measurements.

    What makes TCOMSYS01 different?

    The main contributors to thermal comfort are air temperature, air speed, radiant temperature and humidity. Apart from this, there are personal contributors such as metabolic rate and insulation by clothing.

    Many studies use Fanger’s thermal comfort equation as applied in EN ISO 7730: Moderate Thermal Environments – Determination of the PMV and PPD indices and specification of the condition for thermal comfort. Another approach utilises a globe temperature measurement: EN ISO 27243: Hot environments. Estimation of the heat stress on working man, based on the WBGT Index (Wet Bulb Globe Temperature).

    These methods are quite indirect in particular when determining the heat flow from air speed and radiation.
     

    • TCOMSYS01 offers heat flux measurements. This approach is a lot more direct than the indirect estimate from air speed and radiation.
    • TCOMSYS01 offers directional information.
    • TCOMSYS01 works at a realistic skin temperature of 33 °C (user adjustable).

    Rated operating conditions

    TCOMSYS01 is designed to work between +10 and +25 °C. In its standard configuration, uninsulated and stabilised at 33 °C, it is rated for operation in indoor conditions including significant radiative heating.

    It will stabilise at 33 °C under approximately one of the following conditions:

    • air speeds < 5 m/s
    • irradiance < 400 W/m2
    • ambient air temperature > 5 °C

    Under other conditions, the sensor may not be able to stabilise its body temperature due to overheating (indicating overheating or heatstress) or shortage of electrical power (indication of overcooling or coldstress). Powered using a low voltage, TCOMSYS01 is safe to use.

    TCOMSYS01 may be used for short-term outdoor experiments in the order of weeks. Under long-term exposure to solar radiation, the black heat flux sensor coating may become more reflective.

    User interface: MCU is a web server

    The MCU serves as a web server, and can be connected to any local area network. No more downloading of USB drivers and special interface software! Alternatively it offers an “Ethernet over USB” or virtual Ethernet link, where you connect to the MCU using a USB cable. If you type into your web browser the MCU’s IP address (192.168.66.1 by default), you have access to the user interface.

    Ordering the TCOM01 sensor only

    The sensor TCOM01 is also available as a “sensor only”; The configuration then includes the mannequin with 5 x heat flux, 1 x temperature, 1 x heater, 2 x cable, 2 x chassis connector and 1 x tripod. The user then must combine it with his or her own measurement and control unit.

    Suggested use

    • surveys of human thermal comfort
    • studies of the effect of radiating sources
    • workplace investigations
    • car passenger comfort testing
    • educational purposes, illustrating heat transfer
    • bio-meteorology
    • microclimate studies
    • wind-chill analysis
    • analysis of fabric insulation

    Areas of Application

    • Building physics / insulation, thermal comfort and energy budget measurement >

    TCOMSYS01 Hot Cube

    TCOMSYS01 advantages

    • direct representation of the human body
    • helps understand and quantify the detailed physical cause and effect of thermal comfort
    • simple experiments can be used to quantify the sources of heat gain or loss
    • offers directional information
    • good addition to Wet-Bulb Globe temperature measurement
    • robust, student-proof
    • “stand alone”; equipped with its own clock and memory
    • safe, low voltage power supply
    • communication by (virtual) Ethernet link
    • user interface program on MCU

    Would you like a personalised quote?

    or contact us:

    • info@huksefluxindia.com

    Related products

    Add to quotation basket

    TRSYS20 thermal resistance measuring system

    Heat flux sensors, Heat flux measuring systems
    Add to quotation basket

    BLK – GLD sticker series

    Heat flux sensors, Heat flux sensors
    Add to quotation basket

    STP01 soil temperature sensor

    Heat flux sensors, Soil temperature sensors
    Add to quotation basket

    HTR02 series heater

    Heat flux sensors, Heat flux sensors
    Read more

    FHF05SC series heat flux sensors

    Heat flux sensors, Heat flux sensors
    Add to quotation basket

    SBG01 heat flux meter

    Heat flux sensors, Heat flux sensors
    Add to quotation basket

    FHF06 heat flux sensor

    Heat flux sensors, Heat flux sensors
    Add to quotation basket

    IHF01 heat flux sensor

    Heat flux sensors, Heat flux sensors
    • info@huksefluxindia.com
    • sales@huksefluxindia.com
    Linkedin X-twitter Whatsapp Youtube

    © 2024 HuksefluxIndia

    Cookie & privacy policy

    © Website Designed & Developed By lotus design labs

    • Products
      • Solar radiation sensors
        • Pyranometers
        • Albedometers
        • Pyrheliometers
        • Pyrgeometers
        • Net radiometers
      • Heat flux sensors
        • Heat flux sensors
        • Heat flux measuring systems
        • Soil temperature sensors
    • Applications
      • PV system monitoring
      • Meteorology
      • Building physics
      • Industrial heat transfer
      • Scientific research
      • Thermal simulations
    • Services & Support
      • Application support
      • Pyranometer calibration
      • Downloads
    • News
    • About
    • Contact us
    Quotation Cart
    close
    Start typing to see products you are looking for.